| Status: | Unknown |
|---|---|
| Series: | - |
| RoHS: | Unknown |
No distributors results available
| CE Marking Directive Compliance | Machinery Directive, EMC Directive, RoHS Directive |
|---|---|
| No. of Beam Channels | 8 |
| Protective Height | 160 mm 6.299 in |
| Current Consumption: Large Multipurpose Indicator Lights Off | Emitter: 25 mA or less Receiver: 25 mA or less |
| PFHD | 3.60 × 10-9 (Note) Probability of dangerous failure per hour. |
| Current Consumption: Large Multipurpose Indicator Lights Up | Emitter: 35 mA or less Receiver: 30 mA or less |
| MTTFD | 100 years or more (Note) Mean time to dangerous failure. |
| Net Weight (Total of Emitter and Receiver) | 280 g approx. |
| Applicable Standards: International Standard | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) |
| Applicable Standards: Europe (EU) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
| Applicable Standards: Japan | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) |
| Applicable Standards: North America | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. |
| Operating Range | 0.1 to 3 m 0.328 to 9.843 ft |
| Beam Pitch | 20 mm 0.787 in |
| Min. Sensing Object | ø25 mm ø0.984 in opaque object |
| Effective Aperture Angle | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Power Voltage | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
| Control Output (OSSD) | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less |
| Control Output (OSSD): Operation Mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
| Control Output (OSSD): Protection Circuit | Incorporated |
| Response Time | OFF response: 20 ms or less ON response: 80 to 100 ms |
| Lockout Output (SSD) | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less |
| Lockout Output (SSD): Operation Mode | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
| Lockout Output (SSD): Protection Circuit | Incorporated |
| Interference Prevention Function | Incorporated |
| Test Input Function | Incorporated |
| Large Multi-Purpose Indicator Function | Incorporated |
| Pollution Degree | 3 |
| Operating Altitude | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Environmental Resistance: Degree of Protection | IP65, IP67 (IEC) |
| Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ |
| Ambient Illuminance | Incandescent light: 5,000 â„“x or less at the light-receiving face |
| Ambient Humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Insulation Resistance | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Vibration Resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
| Shock Resistance | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each |
| Emitting Element | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil ) |
| Cable | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long |
| Cable Extension | Extension up to total 50m is possible for 0.3mm2 or more, cable |
| Material | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
| Accessories | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. |
| Directive Compliance | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification |
| Environmental Resistance: Dielectric Strength Voltage | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
Where can I find additional details, specifications and documents for a SF2C-H8-P?
Additional datasheets, footprints and schematics for SF2C-H8-P are listed on our Part Details page. You can also find images and similar parts to SF2C-H8-P on this page.
What pricing and inventory information can I view?
Distributor pricing and stock information is available for SF2C-H8-P on our Product Comparison page. Access via the 'View Pricing & Stock' button to view SF2C-H8-P price breaks, MOQs, lead times, inventory and SKUs from distributors.
What category does SF2C-H8-P fall under?
The SF2C-H8-P is listed under Industrial Automation > Machine Safety / Area Sensors > Light Curtains / Safety Components > Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C.
Can I view similar or alternative parts?
You can view similar parts to SF2C-H8-P when available in the Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C range under the specifications section at the bottom of the details page.
Who can I contact for technical support of the product?
Submit any questions directly to the customer support team of the distributor listing the product. For the SF2C-H8-P you can contact the distributor directly for product support, shipping queries etc.
Is the SF2C-H8-P RoHS compliant?
This part has not been flagged as RoHS Compliant.
Which authorised distributors for SF2C-H8-P have stock available?
There is no stock from authorised distributors for SF2C-H8-P.
How do I check stock and lead times for all distributors?
Stock availability and lead times will be displayed for SF2C-H8-P often in real-time on the comparison pages.
What if I can't find stock of SF2C-H8-P?
You can fill out our help required form which you can use to request a quote for SF2C-H8-P from some of our verified obsolescence suppliers. Alternatively, contact us via our web chat in the bottom left of your screen and one of our team will try to help.