| Status: | Unknown |
|---|---|
| Series: | - |
| RoHS: | Unknown |
| CE Marking Directive Compliance | EMC Directive, RoHS Directive |
|---|---|
| Rated Pressure Range | DPH-L113V : -0.1 to +1 MPa DPH-L113 : 0 to +1 MPa DPH-L133 : 0 to +3.5 MPa DPH-L114 : 0 to +10 MPa DPH-L154 : 0 to +50 MPa (Note) : Values differ depending on a connected sensor head. |
| Set Pressure Range | [DPH-L113V] -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm2 -11.77 to +11.77 bar -170.6 to +170.6 psi [DPH-L113] -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm2 -10.70 to +10.70 bar -155.2 to +155.2 psi [DPH-L133] -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm2 -37.4 to +37.4 bar -542 to +542 psi [DPH-L114] -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm2 -107.0 to +107.0 bar -1552 to +1552 psi [DPH-L154] -53.5 to +53.5 MPa -545 to +545 kgf/cm2 -535 to +535 bar -1980 to +7760 psi (Note) : Values differ depending on a connected sensor head. |
| Set Pressure Resolution | DPH-L113V : 0.001 MPa DPH-L113 : 0.001 MPa DPH-L133 : 0.01 MPa DPH-L114 : 0.01 MPa DPH-L154 : 0.1 MPa (Note): Values differ depending on a connected sensor head. |
| Display | 4 digits +4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Display: Displayable Pressure Range | [DPH-L113V] -0.155 to +1.022 MPa -1.58 to +10.42 kgf/cm2 -1.55 to +10.22 bar -22.4 to +148.2 psi [DPH-L113] -0.050 to +1.020 MPa -0.51 to +10.40 kgf/cm2 -0.50 to +10.20 bar -7.2 to +148.0 psi [DPH-L133] -0.17 to +3.57 MPa -1.7 to +36.4 kgf/cm2 -1.7 to +35.7 bar -24 to +518 psi [DPH-L114] -0.50 to +10.20 MPa -5.1 to +104.0 kgf/cm2 -5.0 to +102.0 bar -72 to +1480 psi [DPH-L154] -2.5 to +51.0 MPa -25 to +520 kgf/cm2 -25 to +510 bar -360 to +7400 psi (Note): Values differ depending on a connected sensor head. |
| Supply Voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Power Consumption | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
| Comparative Output | NPN open-collector transistor (2 outputs) Maximum sink current : 50 mA Applied voltage : 30 V DC or less (between comparative output and 0 V) Residual voltage : 1 V or less (at 50 mA sink current) |
| Comparative Output: Output Operation | NO / NC, selectable by key operation |
| Comparative Output: Output Modes | EASY mode / Hysteresis mode / Window comparator mode |
| Comparative Output: Hysteresis | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
| Comparative Output: Repeatability | Within ±0.2 % F.S. |
| Comparative Output: Response Time | 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Comparative Output: Short-Circuit Protection | Incorporated |
| Analog Output | Output current : 1 to 5 V DC Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V) Span : within 4 V ±0.5 % F.S. Linearity : within ±0.1 % F.S. Output impedance : 1 kΩ approx. Output current : 4 to 20 mA Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V) Span : within 16 mA ±1.5 % F.S. Linearity : within ±0.1 % F.S. Load resistance : 250 Ω (max.) |
| Inputs: Sensor Head Input | Input voltage range : 1 to 5 V DC (over rated pressure range) |
| Inputs: External Input | ON voltage : 0.4 V DC or less OFF voltage : 5 to 30 V DC, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more |
| Operation Indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON ) |
| Protection | IP40 (IEC) |
| Ambient Temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ |
| Ambient Humidity | 35 to 85 % RH, Storage : 35 to 85 % RH |
| Voltage Withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure |
| Insulation Resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Vibration Resistance | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Shock Resistance | 100 m/s2 acceleration in X, Y and Z directions three times each |
| Temperature Characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉ ) |
| Material | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber |
| Connecting Method | Connector |
| Cable Length | Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. |
| Weight (Typ.) | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. |
| Accessories | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set |
| Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉ . The values specified above are applied only to the controller. |
| Digi-Key Electronics United States Tel. 1-800-344-4539 | 1 |
| DIGITAL CONTROLLER FOR DPH-L, NPN WITH 2M CABLE | RS Americas |
Where can I find additional details, specifications and documents for a DPC-L101?
Additional datasheets, footprints and schematics for DPC-L101 are listed on our Part Details page. You can also find images and similar parts to DPC-L101 on this page.
What pricing and inventory information can I view?
Distributor pricing and stock information is available for DPC-L101 on our Product Comparison page. Access via the 'View Pricing & Stock' button to view DPC-L101 price breaks, MOQs, lead times, inventory and SKUs from distributors.
What category does DPC-L101 fall under?
The DPC-L101 is listed under Industrial Automation > Industrial Sensors > Pressure Sensors / Flow Sensors > Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100.
Can I view similar or alternative parts?
You can view similar parts to DPC-L101 when available in the Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100 range under the specifications section at the bottom of the details page.
Who can I contact for technical support of the product?
Submit any questions directly to the customer support team of the distributor listing the product. For the DPC-L101 you can contact the distributor directly for product support, shipping queries etc.
Is the DPC-L101 RoHS compliant?
This part has not been flagged as RoHS Compliant.
Which authorised distributors for DPC-L101 have stock available?
Authorised distributors including RS Americas have stock available or on a lead time for DPC-L101.
How do I check stock and lead times for all distributors?
Stock availability and lead times will be displayed for DPC-L101 often in real-time on the comparison pages.
What if I can't find stock of DPC-L101?
You can fill out our help required form which you can use to request a quote for DPC-L101 from some of our verified obsolescence suppliers. Alternatively, contact us via our web chat in the bottom left of your screen and one of our team will try to help.